Alternativer Identifier:
-
Verwandter Identifier:
-
Ersteller/in:
Seitz, Tobias https://orcid.org/0009-0003-4039-3953 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Walbeck, Marcel [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Hoffmann, Alexander https://orcid.org/0000-0002-9647-8839 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Herres-Pawlis, Sonja https://orcid.org/0000-0002-4354-4353 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]
Beitragende:
-
Titel:
Experimental Data to the publication ""Electron transfer kinetics of a series of copper complexes with tripodal tetradentate guanidine quinolinyl ligands"
Weitere Titel:
-
Beschreibung:
(Abstract) Optimized coordinates otained from DFT calculations, Cyclic Voltammetry measurements and results of stopped-flow UV/Vis spectroscic measurements were deposited.
Schlagworte:
DFT optimized coordinates
Stopped-flow UV/Vis spectroscopic measurements
cyclic voltammetry
Zugehörige Informationen:
-
Sprache:
Englisch
Herausgeber/in:
RWTH Aachen University
Erstellungsjahr:
Fachgebiet:
Chemistry
Objekttyp:
(Dataset) Optimized coordinates otained from DFT calculations, Cyclic Voltammetry measurements and stopped-flow UV/Vis spectroscic data
Datenquelle:
(Instrument) The stopped-flow measurements were performed with a HI-TECH Scientific SF-61SX2 device with a diode array detector. The optical light path for transmission of the quartz glass cuvette was 10 mm.
(Instrument) The measurements were performed with a METROHM AUTOLAB PGSTAT 101 potentiostat using a three-electrode arrangement with a Pt disc working electrode (1 mm diameter), a Pt wire as counter electrode and an Ag/AgCl (in saturated ethanolic LiCl) reference electrode. The measurements were performed in MeCN and 100 mmol/L NBu4PF6 with a sample concentration of 1 mmol/L at room temperature. Ferrocene was added as an internal standard after the measurements of the sample and all potentials are referenced relative to the Fc/Fc+ potential. Cyclic voltammograms were measured with 200 mV·s–1, 100 mV·s–1, 50 mV·s–1 and 20 mV·s–1.
Verwendete Software:
Software für Datenerhebung
Software:
Gaussian 16 - Revision B01
Alternative Software:
-
Verwendete Software:
Software für Datenbetrachtung
Software:
Chemcraft - 1.8
Alternative Software:
-
Verwendete Software:
Software für Datenbetrachtung
Software:
notepad - 7.8.1
Alternative Software:
-
Verwendete Software:
Software für Datenerhebung
Software:
Kinetic Studio - 4.0.8.18533
Alternative Software:
-
Verwendete Software:
Software für Datenbetrachtung
Software:
OriginPro 2021b - 9.8.5.212
Alternative Software:
-
Verwendete Software:
Software für Datenerhebung
Software:
NOVA from Metrohm Autolab - 2.1.5 (Build 7691)
Alternative Software:
-
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:
RWTH Aachen University
Förderung:
Deutsche Forschungsgemeinschaft - (Kontrolle des entatischen Zustands durch die gezielte optische Anregung der Ligandensphäre) 413524714
Name Speichervolumen Metadaten Upload Aktion
Status:
Publiziert
Eingestellt von:
iac_Radar_Produktion
Erstellt am:
Archivierungsdatum:
2024-11-16
Archivgröße:
548,5 MB
Archiversteller:
iac_Radar_Produktion
Archiv-Prüfsumme:
e6eae8992431c213d5edc0df1d2eb740 (MD5)
Embargo-Zeitraum:
-